Unity processor Modicon Quantum – 1056 kB – 66 MHz
- Range of Product
- Modicon Quantum automation platform
- Product or Component Type
- Unity processor
- Clock frequency
- 66 MHz
- Number of slots
- 2, 4, 10, 16, 6
- number of racks
- 2 – local
- number of distributed I/O station
- 63 1 3 Modbus Plus
- number of remote I/O station
- 31 – 2 S908 remote I/O, 0 – 0 ethernet remote I/O
- discrete I/O number
- 31744 inputs, 31744 outputs – remote, 8000 inputs, 8000 outputs – distributed – per network Modbus Plus, Unlimited (26 slots max) – local
- analogue I/O number
- 500 inputs, 500 outputs – distributed – per network Modbus Plus, 1984 inputs,1984 outputs – S908 remote I/O, Unlimited (26 slots max) – local
- Application specific I/O
- Serial link, Counter, High-speed interrupt inputs, Accurate time stamping
- number of optional modules
- 6 Ethernet, Modbus, Modbus Plus, Profibus DP, Sy/Max)
- maximum number of connections
- 2 AS-Interface – distributed, 2 Modbus RS232/485 Modbus/ASCII), 4 AS-Interface – remote, 6 Ethernet TCP/IP – local, 6 Modbus Plus – local, 6 Profibus DP – local
- integrated connection type
- 1 Modbus Plus, 2 Modbus
- Checks
- Process control
- memory description
- Internal RAM 1056 kB
- Switch Function
- Key switch memory start/stop memory protection, Slide switch communication port : ASCII/RTU/Memory
- application structure
- 1 cyclic/periodic master task -, 1 periodic fast task -, 16 timer interrupt tasks -, 64 I/O interrupt tasks -, 64 interrupt tasks -, No auxiliary task –
- execution time per instruction
- 0.1…0.27 µs floating points, 0.1…0.27 µs on fixed-point arithmetic, 0.12…0.585 µs Boolean, 0.12…0.585 µs on word
- number of instructions per ms
- 1.86 Kinst/ms 100 % Boolean, 2.49 Kinst/ms 65 % Boolean and 35 % numerical
- system overhead
- 0.2 ms fast task, 1 ms master task
- Bus current requirement
- 1800 mA
- local signalling
- for communications are active on the Modbus Plus port (Modbus Plus) 1 LED (green), for communications are active on the Modbus port (Modbus) 1 LED (green), for CPU has been started and is solving logic (RUN) 1 LED (green), for CPU has passed the power-up diagnostic tests (READY) 1 LED (green), for write-protected memory (memory port) 1 LED (orange), for battery needs replacing or is not present (BAT LOW) 1 LED (red), for communications error on the Modbus Plus port (ERROR A) 1 LED (red)
- electrical connection
- 1 female connector SUB-D 9 for connecting to the Modbus Plus network, 2 female connectors SUB-D 9 for connecting to the Modbus bus
- Product Certifications
- CSA, CE, UL
- standards
- HazLoc
- Category
- 18150-QUANTUM CONTROLLERS,HSBY,COMM.
- Discount Schedule
- PC21
- GTIN
- 3595863830408
- Returnability
- No
- Country of origin
- FR
- Unit Type of Package 1
- PCE
- Number of Units in Package 1
- 1
- Package 1 Height
- 1.77 in (4.5 cm)
- Package 1 Width
- 6.10 in (15.5 cm)
- Package 1 Length
- 12.20 in (31.0 cm)
- Package 1 Weight
- 21.41 oz (607.0 g)
- Unit Type of Package 2
- S03
- Number of Units in Package 2
- 7
- Package 2 Height
- 11.81 in (30.0 cm)
- Package 2 Width
- 11.81 in (30.0 cm)
- Package 2 Length
- 15.75 in (40.0 cm)
- Package 2 Weight
- 9.37 lb(US) (4.249 kg)
- Warranty
- 18 months